RigSiz

Synthetic Rigging Sizing

HMPE Stretch-Equivalent Calculator

Wire diameter

mm

Common diameters (mm)

Stretch-equivalent HMPE

— mm

Rounded up to a whole millimetre

Calculated diameter— mm

About this calculation

Nick Parkyn’s method sizes HMPE for equivalent axial stiffness. Equivalent breaking strength is a separate requirement.

  1. Multiply the squared wire diameter by 0.597 to obtain the metallic area of the 1×19 wire.
  2. Multiply that area by the ratio of stainless steel modulus (200 GPa) to Dyneema modulus (115 GPa).
  3. Convert the resulting area to a circular diameter and round it up to the next whole millimetre when needed.

The fixed moduli represent material assumptions. The calculated diameter is displayed to three decimal places, and upward rounding uses the full calculated value.

This calculator provides preliminary stretch-equivalent sizing based on fixed material assumptions. Actual rope stiffness, construction, creep, breaking strength, terminations and safety factors must be independently verified. This calculator is not a substitute for professional rigging assessment.